READ AND SAVE THESE INSTRUCTIONS Before beginning installation, please thoroughly read and become familiar with these instructions. Installation and service must be completed by a qualified installer. Failure to properly install this product may void the warranty.
Installer: Please leave these installation instructions with the range hood. Owner: Please keep these installation instructions for local electrical inspector's use and for future reference.
|
|
WARNINGS: Must be followed carefully to avoid personal injury |
|
IMPORTANT: Must be followed carefully to avoid damage |
|
|
TIPS: Contain helpful information |
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:
-
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
-
Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnection means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.
-
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
-
Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) or fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (ASHRAE) and the local code authorities.
-
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
-
Duct fans must always be vented to the outdoors.
WARNING! TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
-
Never leave surface units unattended at high settings. Boil-overs may cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
-
Always turn hood ON when cooking at high heat or when cooking flaming foods.
-
Clean filters and ventilation fans frequently. Grease should not be allowed to accumulate on filter or fan.
-
Use proper pan size. Always use cookware appropriate for the size of the surface element.
 WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING*:
-
SMOTHER FLAMES with a close-fitted sheet of metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
-
NEVER PICK UP A FLAMING PAN -- you may be burned.
-
DO NOT USE WATER, including wet dish cloths or towels -- a violent steam explosion will result.
-
Use an extinguisher ONLY if: -- You have a Class ABC extinguisher, and you already know how to operate it. The fire is small and contained in the area where it started. The fire department is being called. You can fight the fire with your back to an exit.
*Based on "Kitchen Fire Safety Tips" published by the NFPA.
 CAUTION: Turn Off Electrical Power First
-
Your Air-O Hood has been tested and packaged ready-to-use, requiring no further assembly, only installation.
-
After removing hood from carton, slide out aluminum mesh grease filter.
-
Unscrew and remove the electrical outlet box cover located at the side of the motor compartment.
-
Position hood against cabinet bottom with back against wall. Mark 4 hole locations, then lay hood aside. Drive #10 screws halfway into these locations and remove. If necessary to use furring strips to provide a solid base for mounting. The bottom of the range hood should be installed a minimum of 30” above cooking surface.
-
For venting Air-O-Hoods, mark the duct hole location on bottom of cabinet or vertical wall and cutout. For round duct models, install damper in duct collar with butterfly louvers opening upward. For rectangular 3 ¼” x 10” duct models, reinstall the damper assembly. On back mounted dampers the hinge pivot should be at the top; on top mounted, the hinge should be in the back.
-
Bring 120 volt power cable through wall or cabinet. Install an approved 7/8” power supply connector (not furnished).
-
Position hood on 4 screw holes at bottom of cabinet. Bring power cable through connector, and on vented models seal ductwork over duct collar. Align hood with cabinet and tighten screws.
-
Connect the black wire from the power supply cable to the black wire in the electrical outlet box. Repeat procedure with the white wires using wire nuts or any other suitable insulated connector. Ground the unit according to local code. Replace the electrical outlet box cover.
-
On vented models, secure ductwork to collar with sheet metal screws or furnace tape. Be sure the damper shutter moves freely.
-
Install maximum 60-watt light bulb.
-
Replace filter or filters.
-
Turn on electrical power and your Air-O-Hood is now ready to use.
Warranty
What is Covered
Universal Metal Industries, Inc., warrants its Air-O® and Trade-Wind® brand products to the original user, to be free of defects in materials and workmanship for one (1) year from the date of purchase.
Universal Metal Industries, Inc., at its option, will repair or replace the complete unit or any defective component without charge providing that if requested, the product or defective component is promptly returned, prepaid to the address below. This warranty may be voided if any unauthorized service, alterations or repairs are made to the product.
What is Not Covered
· Normal maintenance and service of any product that has been subject to misuse, negligence, accident or installation inconsistent with the recommended installation instructions.
· Product used other than for normal in-home use or products used outside of the United States.
· Damage to the product caused by accident, fire, flood or other acts of God.
· Service calls to educate the customer in the proper use and care of the product, correct faulty installation, change fuses or reset breakers.
Universal Metal Industries, Inc. disclaims and excludes any liability for implied warranties or for incidental or consequential damages wherever permitted by law. There are no implied warranties of merchantability or fitness for a particular use or purpose. This warranty gives you specific legal rights and you may also have other rights, which vary from state to state.
For Service
If you need service, contact Customer Service at the address or phone number below. Provide the model number, part identification and details of the problem. Proof of purchase must be provided.
HVI-2100 CERTIFIED RATINGS comply with the new testing technologies and procedures prescribed by the Home Ventilating Institute for off-the-shelf products as they are available to consumers. Product performance is rated at 0.1 inch static pressure, based on tests conducted in an independent state-of-the-art test laboratory. Sones are a measure of perceived loudness, based on laboratory measurements.
|
Universal Metal Industries, Inc. has a policy of continuous improvements and reserves the right to modify (at any time, without notice) any or all of its products, features, designs, components, and specifications. For exact dimensions, see the installation instructions included with each product. Some features may be slightly different than shown on product literature.
|